TB-0908 — DCI® Performance in Cracked Concrete

Introduction

A laboratory study was conducted for three years to test DCI® corrosion inhibitor performance in cracked concrete. An accumulation of all corrosion measurements or total corrosion of the steel is presented here.

Three sets of specimens were produced in 100 mm x 125 mm x 405 mm (4 in. x 5 in. x 16 in.) molds with 32 mm (1 1/4 in.) of cover over a number three rebar. The first set was third point loaded to produce a crack down to the rebar, the second set loaded to produce a crack halfway down to the rebar, and the third set remained uncracked. Half the test specimens contained DCI® corrosion inhibitor at 20 L/m3 (4.0 gal/yd3) of concrete while the remaining specimens were unprotected references. All concrete had a water/cement ratio of 0.45 and an average cement factor of 410 kg/m3 (690 lb/yd3). The specimens were alternately ponded with a 3% sodium chloride solution and then dried on a weekly basis. This laboratory study is considered to be more severe than actual field conditions. Corrosion potentials, corrosion rates, total corrosion and specimen appearances were monitored every month. Concrete cracks measured .23 mm (0.009 in.) at the surface.

Figure 1

J

Results

  • As shown in Figure 1, DCI®-protected concrete specimens have much lower total corrosion than their corresponding unprotected references.
  • The fully-cracked, DCI®-protected specimens have total corrosion less than that of the unprotected half-cracked concrete specimens.
  • The DCI®-protected, half-cracked to the rebar specimens have total corrosion equivalent to that of the unprotected, uncracked concrete specimens.
  • The unprotected, full-cracked reference specimens have developed severe corrosion. Staining and rust-caused cracking has begun. This is in good agreement with other studies that show that over .0254 mm (1 mil) average corrosion will induce concrete cracking. The DCI®-protected, fully-cracked specimens do not show these signs of distress.

Recommendations

The use of DCI® corrosion inhibitor in concrete will help control the corrosion of steel reinforcement and strands when chlorides are present in concrete where cracking may develop.

 

gcpat.com | North America Customer Service: +1 (877) 423 6491

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

DCI® is a trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status. These products may be covered by patents or patents pending.

© Copyright 2018 GCP Applied Technologies Inc. All rights reserved.

.

In Canada, 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6.


GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 475, Alpharetta, GA 30009, USA
GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6
This document is only current as of the last updated date stated below and is valid only for use in the United States. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.

Last Updated: 2024-06-21

https://gcpat.com/en/solutions/products/dci-corrosion-inhibitor/tb-0908-dci-performance-cracked-concrete