UL Designs & Thickness — Floor Assemblies


Click here for Roof Assemblies and Columns

 categoryDescriptionUL design LinkUL PDFCAD DrawingUnrestrained thickness tablerestrained thickness table
 
Unprotected Floor/Ceiling 
      
  CellularD925UL PDFDWGD925N708
  NWC FlutedD925UL PDFDWGN852N852
  LWC FlutedD925UL PDFDWGN782N852
 Non-Load Restricted2-1/2" NWC, FlutedD985UL PDFDWGN782N852
 Non-Load Restricted2-1/2" LWC, FlutedD985UL PDFDWGN782N852
 Non-Load Restricted4-1/2" NWC 2HR only, FlutedD985UL PDFDWGN852 4 1/2" tableN852 4 1/2" table
 
Unprotected Future Floor/Ceiling ​
      
  NWC, Fluted/Cellular D925UL PDFDWGD925 FF NWCD925 FF NWC
  LWC, Fluted/Cellular D925UL PDFDWGD925 FF LWCD925 FF LWC
 
Beam/Unprotected Floor Substitution
      
  CellularN708UL PDFDWGN708 Cellular UnN708 Cellular Re
 Non-Load RestrictedNWC, FlutedN852UL PDFDWGN852N852
 Non-Load Restricted4-1/2" NWC 2HR only, FlutedN852UL PDFDWGN852 4 1/2" tableN852 4 1/2" table
 Non-Load RestrictedLWC, FlutedN852UL PDFDWGN852N852
  NWC, FlutedN782UL PDFDWGN782N782
  LWC, FlutedN782UL PDFDWGN782N782
  Castellated BeamN784UL PDFNAN784N784
  Joist SubstitutionN854UL PDFDWGRefer to DesignRefer to Design
 Non-Load RestrictedJoist Substitution N854UL PDFDWGRefer to DesignRefer to Design
 Non-Load RestrictedTube Steel (HSS)GCP/CF 194-01PDFNARefer to DesignRefer to Design
 
Protected Floor/Ceiling 
      
  2 1/2" NWC/LWC, Fluted/CellularD739UL PDFDWGD739N782
  2" NWC/LWC, Fluted/Cellular D743UL PDFDWGD743S750
  2 1/2" LWC, FlutedD779UL PDFDWGN782N782
  2 1/2" NWC, FlutedD779UL PDFDWGN782 NWC UnN782
  Corrugated DeckD780UL PDFDWGD780S750
  3 1/4" LWC, FlutedD782UL PDFDWGN782 unN782 Re
  4 1/2" NWC, FlutedD782UL PDFDWGN852 4 1/2" tableN852 4 1/2" table
 Non-Load Restricted2-1/2" NWC, FlutedD798UL PDFDWGN852 LWC UnN852
 Non-Load Restricted2-1/2" LWC, FlutedD798​UL PDFDWGN852N852
 
Beam Protected Floor Substitution ​ 
      
  Beam Supporting Cellular Deck NWCN706UL PDFNAN706N706
  Beam Supporting Cellular Deck LWCN706UL PDFNAN706N706
  Beam Supporting Fluted DeckN782UL PDFDWGN782 unN782 Re
 Non-Load RestrictedBeam Supporting Fluted DeckN852UL PDFDWGN852N852
  Joist SubstitutionN854UL PDFDWGRefer to DesignRefer to Design
 Non-Load RestrictedTube Steel (HSS)GCP/CF 194-01PDFNARefer to DesignRefer to Design
 
Concrete Decks 
      
  Concrete Slab with Concrete Beam SupportJ701UL PDFNARefer to DesignRefer to Design
  NWC Slab with Beam SupportJ709UL PDFDWGN852N852
  NWC Slab with Beam SupportJ712UL PDFDWGN782N782
  Concrete Hollow Core Slab with Beam SupportJ957UL PDFDWGJ957S735**
  Tube Steel (HSS)GCP/CF 194-01PDFNARefer to DesignRefer to Design

*Per UL N or S series design may be substituted for beams in D and J series designs
** Final Design is dependent on overall concrete thickness

Click here for explanation of Future Floors

 

gcpat.com | North America Customer Service: +1 (877) 423 6491

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation or suggestion is intended for any use that would infringe any patent, copyright or other third-party right. 

Monokote and Spatterkote are trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies, Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status. 

© Copyright 2025 GCP Applied Technologies, Inc. All rights reserved.


GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA
GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6
This document is only current as of the last updated date stated below and is valid only for use in the United States. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.

Last Updated: 2025-01-09