PERM-A-BARRIER® HRA PROTECTION G Data Sheet

SBS-Modified Protection Sheet Reinforced with Fiberglass for Waterproofing Systems

Product Description

PERM-A-BARRIER® HRA PROTECTION G is a SBS modified membrane reinforced with a tough glass fabric for use as the top protection layer on hot rubberized asphalt waterproofing systems. It protects the underlying system from moderate abuse due to construction foot traffic and overburden. Additionally, this membrane may be used as the base ply in vertical two ply flashings. 

For other HRA system products see the individual product data sheets

Product Details

PERM-A-BARRIER HRA PROTECTION G is manufactured on a strong fiberglass reinforced mat that receives a heavy coating of superior SBS-modified bitumen compound. It is manufactured on state-of-the-art, dedicated lines that were exclusively designed to produce modified bitumen products.

Roll Dimensions39⅜" X 49' 6"
Nominal Coverage150 sf/roll
Approximate Weight88 Ibs. per roll
Top SurfaceFine sand release agent
Back SurfaceFine sand release agent
Applicable StandardsMeets ASTM D6163 Grade S, Type I

System Components

PERM-A-BARRIER® HRA – Hot Rubber Membrane
PERM-A-BARRIER® HRA FABRIC– Polyester Reinforcement
PERM-A-BARRIER® HRA NEOPRENE 12” x 100’ – Neoprene for Flashing
PERM-A-BARRIER® HRA NEOPRENE 6” x 100’ – Neoprene for Flashing
PERM-A-BARRIER® HRA PROTECTION G – Fiberglass Protection Sheet
PERM-A-BARRIER® HRA PROTECTION P – Polyester Protection Sheet
BITUTHENE® ADHESIVE PRIMER B2 LVC
PERM-A-BARRIER® HRA CAP – Cap Sheet for Wall Flashing 

Safety & Handling

PERM-A-BARRIER® products must be handled properly. Do not handle until all safety precautions and instructions have been read and understood. Refer to product label and SDS before use.  SDSs can be obtained from www.gcpat.com or by contacting your local representative.


STORAGE & USE

Rolls should be stored upright off the ground and completely protected from the weather. Substrates must be structurally sound, dry, smooth, and meet or exceed minimum requirements of local codes and GCP. Do not attempt application if ice, snow, moisture, or dew are present or inclement weather is expected.  


APPLICATION

PERM-A-BARRIER HRA PROTECTION G must be applied in accordance with GCP installation procedures. The following information is intended for general information purposes only and is not all-inclusive.

When used as a protection layer, PERM-A-BARRIER HRA PROTECTION G is installed in a shingle pattern to promote drainage. Install membrane while the PERM-A-BARRIER HRA is hot and has a tacky consistency.  Overlap protection course side laps a minimum of 2" (50.8 mm) and end laps a minimum of 4” (101.6 mm).  Ensure overlaps are secured tightly with hot rubberized asphalt.

When used as a base membrane in vertical flashing applications, substrates to receive the membrane must be firmly attached, smooth, dry, clean, and free of sharp projections and depressions.  Substrates requiring priming must be primed with BITUTHENE® ADHESIVE PRIMER B2 LVC and allowed to dry. Install PERM-A-BARRIER HRA PROTECTION G in a solid mopping of hot rubberized asphalt with 3" (76.2 mm) side side laps and membrane extending a minimum of 4" (101.6 mm) into the field. Ensure overlaps are secured and fully adhered. No additional HRA material is needed.
                                                                                                                          
Cold weather applications require special handling to prevent damage to the rolls and ensure satisfactory installation. Do not apply waterproofing systems over improperly prepared substrates or substrates that contain moisture. Rubberized asphalt temperature in the melter must be 380°-400°F (193°-204°C) to ensure proper adhesion.


PHYSICAL PROPERTIES

Test Description  Test Method  Results*
Softening PointASTM D36260°F
Tensile StrengthASTM D5147
@ 73.4 +/- 3.6°F MD/XD
@ 0 +/- 3.6°F MD/XD
60/60 lbs./in.
135/125 lbs./in.
ElongationASTM D5147
@ 73.4 +/- 3.6°F MD/XD
@ 0 +/- 3.6°F MD/XD
4%/4%
4%/4%
Dimensional StabilityASTM D5147 MD/XD0.1%/0.1% MAX
Low-Temperature FlexASTM D5147Pass @ -20°F
Compound StabilityASTM D5147 250°F
ThicknessASTM D5147 2.3 mm (91 mils)
Tear Strength ASTM D5147
@ 73.4 +/- 3.6°F MD/XD 
115/120 lbs

*NOTE: Published results are nominal production values confirmed by independent laboratory testing.

TECHNICAL ASSISTANCE & SERVICES

GCP provides technical assistance in the product selection, specification and application guidelines for all GCP HRA systems. Field representatives are available for consultation in each region.
For more information, contact GCP Technical Services.
 

gcpat.com | North America Customer Service: +1 (877) 423 6491

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

PERM-A-BARRIER is a trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.


GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA
GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6
This document is only current as of the last updated date stated below and is valid only for use in the United States. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.

Last Updated: 2024-11-18

https://gcpat.com/en/solutions/products/perm-a-barrier-hra-waterproofing-system/perm-a-barrier-hra-protection-g-data